The NEUMOVENT Graph is a pneumatically powered,
microprocessor-controlled ventilator primarily for use in the
ICU for neonatal, pediatric, or adult patients. It includes
up-to-date modes of ventilatory support plus pressure, volume
and flow curves, and pressure-volume or flow-volume
loops. Its operation is based on the action of two, high
quality, proportional valves joined to an electronic board
with a microcontroller. The monitor is a LCD color screen. It
provides, besides waveforms, information about selected and
measured parameters. Also it shows trends of relevant data and
alarm messages. During the ventilatory procedure the
respiratory mechanics option allows measurement of dynamic
and static compliance and resistance, auto PEEP, P0.1, and
slow vital capacity. The panel design and the direct selection
of the operative mode make this ventilator a comprehensible
device easy to
adjust according to the patients ventilatory requirements.
|
|
| |
Modes of
Operation |
| |
 |
Adult and Pediatric |
| |
| |
Volume-Controlled
(VCV), Assist/Control Pressure-Controlled (PCV),
Assist/Control Pressure Support (PSV) CPAP +
PSV SIMV (VCV) + PSV SIMV (PCV) + PSV
Mandatory Minute Ventilation (MMV) + PSV PSV +
Tidal Volume Assured |
|
|
| | |
|
|
 |
Neonatal |
| |
| |
Pressure Controlled (PCV),
Assist/Control Pressure Support (PSV) CPAP SIMV
(PCV) + PSV Continuous Flow, Time Cycled, Pressure
Limited |
| |
 |
Apnea Ventilation (back-up) |
| |
| |
VCV or PCV for adult and pediatric
patients; PCV for neonates. |
| |
 |
Panel Controls and Operating Range |
| |
| |
Tidal Volume: 50 to 2500 mL (Adult and Pediatric
Category) Flow Waveform: In VCV: Square,
Decelerating, Sinusoidal, Accelerating. In PCV and PSV:
Decelerating. Pressure Control (PCV): 1-50 cm
H2O, with
rise time. Pressure Support (PSV): 0-50 cm
H2O, with
rise time and exp. sensitivity. Rise Time: Modify
the pressure slope. Expiratory Sensitivity: 40, 33,
25 (default), 15, 10 and 5% of peak flow. Respiratory
Rate: 1-150 bpm Sensitivity (PEEP compensated):
Trigger pressure: 0.5 to 10 cm H2O Trigger flow: 0.5 to 5 L/min Inspiratory
Time: 0.1 - 3 seconds PEEP/CPAP: 0 to 50 cm
H2O Sigh (VCV only): Number, Events per hour,
Volume, and Max.Pressure. Insp. Pause (VCV only):
0.25 to 2 seconds with 0.25 s increments. I:E Ratio:
Volume mode: 1:1 1:20; Pressure Control: 5:1
1:20 FIO2 :
0.21 1.0 O2 100%:
120 s with 30 s in the middle time for
suction. Stand-by: To stop the ventilator saving
selected parameters. |
| |
 |
Measured Parameters |
| |
| |
Peak
Flow Airway
Pressure: Peak, Plateau, Mean, Base.
Expiratory Time.
Inspiratory Time and I:E Ratio of spontaneous
breaths. Expired
Tidal Volume. Expired
Minute Volume. |
| |
 |
Graphic Display Screen |
| |
| |
Selection of pressure, volume and flow vs. time waveforms, and
pressure/volume and flow/volume loops. Sweep
speed selection of horizontal axis to 3, 6 and 12 seconds.
Three scales for change the vertical axis. Timed
graphics can be frozen and
all the screen printed to a PC file or compatible
printer. Trends
of tidal volume, minute volume, rate, peak and base pressure,
peak flow and dynamic compliance of the last 3, 6, 12
and 24 hours. Pressure
bar graph showing airway pressure with two scales (0-60,
0-120 cm H 2 O). |
| |
 |
Alarms |
| |
| |
High and
Low Inspiratory Pressure High and
Low Tidal Volume High and
Low Minute Volume
Apnea High
breathing rate Low
PEEP Low
driving gas pressure Power
loss Battery
low charge
Technical Alarm
Silence: 3060 s The alarms
are activated according to levels of priorities with audible
and visible (light) signals, and simultaneous written
messages on the screen.
Each event is documented in a list with date and
hour. |
| |
 |
Respiratory Mechanics |
| |
| |
AutoPEEP Static and Dynamic
Compliance Static and Dynamic Resistance Slow Vital
Capacity P0.1 |
| |
 |
Electrical |
| |
| |
Voltage range: 100 240 ACV
(auto-switching) Frequency: 50-60 Hz; Power: 50 watts 12
V internal rechargeable battery: Operating time: At least 30
minutes. |
| |
 |
Pneumatic |
| |
| |
Pressurized Oxygen: 2.9 - 6.9 bar (42-100
psi). DISS connector inlet. Pressurized Air: 2.9 - 6.9 bar
(42-100 psi). DISS connector inlet. |
| |
 |
Standard Accessories |
| |
| |
Reusable
adult breathing circuit ( 22 mm) with water
traps, exhalation
flow sensor with expiratory valve. Flex arm
for breathing circuit. Air and
oxygen high pressure hose with DISS
connectors.
Compressed air water trap. Test
lung. Power
cord.
Pedestal: Four-wheel stand.
Operating instruction manual |
| |
 |
Optional Accessories |
| |
| |
Heated
humidifier.
Pediatric circuit ( 15 mm). Neonate
circuit ( 12 mm). |
| |
 |
Warranty |
| |
| |
One year warranty on material and
workmanship. |
| |